Neuron Spectrum AM (PSG)

Description

Keunggulan:

  • Recording of exams to memory card and real time data transfer via Wi-Fi
  • Full set of PSG channels (acording to AASM recommendational)
  • Ambulatory PSG recording (up to several days)
  • Full set polygraphic channels for PSG recording
  • High quality channel EEG acquisition with up to 1000 Hz Sampling rate
  • One battery charge is enough for more than 24 hour acquisition in the autonomous mode
  • Up to thousand hours of exams can be save to SD memory card with up to 32 GB size
  • Synchronous video recording using both analogue and network cameras (including wireless ones)
  • Full autonomous recorder allows performing the exams with video monitoring ambulatory
  • Wireless connection to PC makes petients feel comfortable during the exam and allows EEG specialist to perform real time EEG analysis
  • Continuous impedance measurement during the acquisition allows keeping proper electrode placement in good time
  • Control of recorded data with on line detection of epileptiform activity and calculation of vital parameter (HR, Airflow rate, SpO2)
  • Warning message to notify when patien's parameters exceed the specified level is sent to preset email. It allows EEG specialist to control patien's state all the time
  • The option of deleyed start acquisition is intended to start or stop the acquisition at preset time. It is especially useful for PSG recordings.
  • Battery hot swapping during the acquisition allows performing long term exams (up to several days)
  • Neuron Spectrum AM creates a backup copy of performed exam on SD memory card to avoid information loss even if patients leave WiFi zone. These data can be uploaded to any PC, tablet or smartphone via WiFi

Exellence

LED Photic Stimulator
Power consumption : not more than 2.5 W
Stimulation frequency range : from 0.1 to 100 Hz
Brightness range : from 0 to 100 % with 1 % step
Pulse duration range : from 0.1 to 1000 ms with 0.1 ms step
Adjustable delay time relative to external trig-in pulse : from 0.6 to 1000 ms with 0.1 ms step
General Specifications and Parameters
Interface : Wi-Fi IEEE-802.11b/g/n
Memory type and capacity : SD removable memory card (not more than 32 GB)
Supply voltage: : 3.6 to 6.5 V (4 АА batteries)
· electronic unit : 220/230 V AC (50 Hz)
· desktop PC-based system : 220/230V AC (50 Hz)/int. battery
· notebook PC-based system :
Continuous operation from one battery set: : 24 hours
· without radio channel : 8 hours
· with a radio channel :
Synchronous Review PSG & Video : Include Camera Full HD
Minimum Personal Computer
i5, 6GB RAM, 500 GB HDD, & Windows 10
Color Printer & LED Monitor
Software
Export format avi, txt, rtf, xml, bmp, emf, EDF, pdf
Report automatically generated EEG report
PSG Software
Single / All channel editor
Single/ Multiple channel measurement
Magnifier Mode
Automatic detection of spikes and sharp waves
Automatic artifact detection
Bandpass Filter : Delta, Theta, Alpha, Beta, or custom rhytem
Spectral Analysis : Spectrum graph, spectrum table, spectrum map
Manual, semi-automatic and automatic sleep staging and PSG event detection

 

Specification

EEG, EMG, EOG & ECG Channels
Number of channels : 23
Input voltage measurement range : 2 to 12000 µV
Admissible error of input voltage measurement:
· in the range from 2 up to 10 µV : not rated
· in the range from 11 up to 50 µV : within ±25 %
· in the range from 51 up to 12000 µV : within ±7 %
Relative measurement error of time interval within the range from 10 µs up to 10 s : within ±2 %
Sweep speed range during EEG signal recording : 1 to 10000 mm/s
Admissible relative error of sweep speed setting : within ±2 %
Sensitivity during EEG signal recording : 1 to 10000 µV/mm
Admissible relative error of sensitivity setting : within ±5 %
Filters with the option to choose a bandpass frequency range at minus (3 ± 0.5) dB level : yes
High pass filter : 0.05, 0.5, 0.7, 1.5, 2, 5, 10 Hz
Low pass filter : 5, 10, 15, 35, 75, 100, 150 Hz
Noise reduction filter at 50 and 60 Hz frequencies with reduction of not less than 40 dB : yes
Common mode rejection at 50 Hz frequency : not less than 110 dB
Bandpass flatness:
· in frequency range from 0.5 to 75 Hz relatively 10 Hz frequency : within the range from –10 to +5 %
· in frequency range from 76 to 150 Hz : within the range from –30 to +5 %
Direct bias voltage : ±300 mV
Input noise level (peak-to-peak) in the range from 0.5 to 35 Hz (rms value) : not more than 2 µV (RMS) (not more than 0.35 µV)
Patient leakage current : not more than 50 nA
Option to choose sampling rate for input signals out of 100, 200, 500, 1000 Hz : yes
Input impedance : not less than 400 MΩ
Snoring Channel (for Snoring Sensor)
Number of channels : 1
Input signal range : from –100 mV to +100 mV
Low pass filter at – 3 dB level : 5, 10, 15, 35, 75, 100, 150, 200 Hz
High pass filter at – 3 dB level : 0.016, 0.05, 0.5, 0.7, 1.5, 2.0, 10 Hz
Chest and Abdominal Respiratory Effort Channel
Number of channels : 2
Input signal range : from –100 mV to +100 mV
Bandpass at minus (3 ± 0.5) dB level : from 0.05 to 20 Hz
Airflow Channel
Number of channels : 1
Respiratory waves display range : from 0.1 to 1.5 Hz
Bandpass at minus (3 ± 0.5) dB level : from 0.05 to 7.5 Hz
Respiratory channel
Number of channels : 1
Respiratory waves display range : from 0.1 to 1.5 Hz
Bandpass at minus (3 ± 0.5) dB level : from 0.05 to 7.5 Hz
Nama Produk : Wireless Digital Polysomnograph / PSG
Merk : Neurosoft - Russia
Model : Neuron Spectrum AM with PSG
Control of electrode impedance during the acquisition

 

SpO2 Channel
Number of channels : 1
Type of built-in module : OEM III module
Displayed oxygen saturation range (SpO2) : (Nonin® Medical, Inc. USA)
Display features: : 0 % to 100 %
· SpO2 : 3-digit numeric sensor fault
· indicators : 70-100
Measurement wavelengths and output power**
· Red : 660 nanometers @ 0.8 mW maximum average
· Infrared (using Nonin PureLight® Sensor) : 910 nanometers @ 1.2 mW maximum average
Direct Current Channel
Number of channels : 1
Voltage range : from –10 to +10 V
Bandpass : from 0 to 20 Hz
Light Channel
Number of channels : 1

 

 

 

 

Standard Configurations

Neuron-Spectrum-AM electronic unit : 1
PSG Stater Kit
License for EEG software module : 1
License for PSG : 1
Aksesoris Lokal:
PC : 1
Monitor : 1
Printer : 1
Trolley : 1
UPS : 1
Camera : 1
Speaker : 1