Neuro MS/D Therapeutic with EEG

Description

Application: psychiatry, neurology

The principle of therapeutic magnetic stimulation is based on the following. The magnetic stimulator uses the magnetic pulses of short duration. The emerging high-intensity electromagnetic field easily penetrates through clothes, cranium bones and soft tissues. It impacts on deep nerve centers, peripheral nerves, cerebral and spinal cord, which is inaccessible for other kinds of stimulation.
This stimulation is commonly used to treat depressions (including severe and drug-resistant), tinnitus. Besides, there are positive and encouraging results obtained at rehabilitation of post-stroke patients and other neurological and psychiatric diseases.

Psychiatry:

Treatment of depressions, schizophrenia, obsessive-compulsive disorders, post-traumatic stress, manias and other psychiatric disorders.

Neurology:

Treatment of central and peripheral nervous system disorders: neuropathic pain, stroke, migraine, Parkinson disease, epilepsy, tinnitus etc.

Solution for therapeutic repetitive transcranial magnetic stimulation (rTMS)

It includes main unit with cooling system and cooled coil placed in a flexible arm that ensures fast and easy coil fixation in any position by rotating one screw. All that is mounted on a smooth-running trolley. The computer to control the stimulation can be also included in the delivery set. In this configuration system allows performing long-term sessions of biphasic rTMS with up to 30 Hz frequencies and up to 5 Hz maximum intensity.

Select any Neurosoft EMG recorder from a wide list of neurophysiological systems to record motor evoked potentials (MEPs).

Number of pulses generated during one session – up to 10 000

The cooling unit and cooled coils included in the delivery set of Neuro-MS/D are intended to avoid overheating of coils during the long-term treatment session. The cooling unit itself is a tank with the cooling liquid, the pump running the cooling liquid through the coil and the fridge. The unit allows increasing continuous operation of up to 10 000 pulses without overheating. Practically, it means that stimulator can operate for hours without overheating.

Neuro-MS.NET software to control magnetic stimulator

This delivery set includes a special Neuro-MS.NET software that allows customizing any stimulation protocols. This software keeps patient database, determines motor response threshold and controls the stimulation courses and sessions. You can perform the stimulation according to pre-defined ptorocols and also create your own ones or customize the preset stimulation programs.
Preset protocols are used to treat depression, Parkinson disease, stroke, tinnitus, etc.

32 EEG Channels + 9 Additional Channels

Neuron-Spectrum-5 is a versatile and expandable 32-channel digital EEG system with a large number of high-quality polygraphic channels to record any physiological signals from EOG to short-latency EP.

11 Types of EEG Analysis Including Online/Offline Mapping and Epileptiform Activity Detection

The supplied software allows performing various types of EEG analysis including amplitude, spectral, coherence, periodometric, correlation, cross-correlation, comparative, wavelet, independent component, and epileptiform activity. The software can generate two- and three-dimensional brain maps of the whole record or selected trace fragment. All the results are synchronized with recorded traces.

Impedance Measurement Button on the Front Panel

For better usability, the impedance/acquisition button is located on the front panel of the unit. It allows a user to check electrode placement quality shown by LED indicators just at the patient's spot without computer assistance which is much timesaving. You can also start EEG signal acquisition using the same button.

12 Options to Expand the Device Functions

The system options can be expanded with long-term monitoring, polysomnography, cerebral function monitoring, short- and long-latency EP, EMG and ERG modules. A compact device with a wide range of options is the best choice for private clinics and family doctors.

License for Unlimited Workstations

Neuron-Spectrum.NET software can be installed on an unlimited number of PCs in the office and at home ensuring the full range of options available including report generation. 

Exellence

     
  • Transcranial Magnetic Stimulator (TMS) untuk diagnostik dan terapetik pada cerebral cortex motor zones
  • Main unit dengan digital indicator dan control knob yang mudah dioperasikan
  • Dilengkapi dengan 2 coil (transcranial dan peripheral)
  • Modul Active coil cooling unit terpisah (bukan pada coil) tanpa compressor dengan sistem sirkulasi oil untuk mengontrol temperatur pada coil sehingga terapi dapat dilakukan secara terus menerus sampai dengan 10.000 pulse per sesi terapi tanpa menimbulkan overheat pada coil dan dengan TINGKAT KEBISINGAN YANG RENDAH
  • Software Neuro-MS.NET dengan pre loaded treatment protocol dan dapat ditambahkan dengan treatment protocol sesuai keinginan pemakai
  • Frequency sampai dengan 30 Hz (apabila ditambahkan dengan optional extra power supply model dapat mencapai hingga 100 Hz) untuk kasus kasus yang memerlukan high frequency
  • Kekuatan peak magnetic field sampai dengan 4 Tesla
  • Fungsi Neurologi
: : Diagnostik untuk corticospinal pathways pathology, treatment tinnitus, rehabilitasi motor disorder pasca stroke, spaticity, migraine, parkinson dll
  • Fungsi Psikiatri
: Treatment depresi, schizophrenia, obsessice compulsion disorder (ocd), mania dll
  • Mode stimulasi
: Tonic, Burst ( Theta burst, Alpha burst, Beta burst) , single pulse, pair pulse
  • Compatible dengan semua merk TMS navigation (belum termasuk)
  • Dilengkapi unit EEG sebagai diagnostic QEEG & Brain Mapping untuk melihat gambaran otak sebelum dan setelah di therapy
  • EEG channel 32 + 8 additional channel (EMG, ECG, EOG, SpO2, etc)
  • QEEG with 2 & 3D Mapping
  • QEEG with 2 & 3D Mapping
  • Epileptic Seizure Detection

 

Specification

           

Stimulation Parameters:

  • Pulse Duration
   

 

   
  • Standard biphasic
: 250–330 µs
  • Maximum frequency at maximum power
: 5Hz2
           

Power Supply:

  • Maximum power consumption during the stimulation
  • Supply Voltage
: (220±22)/(230±23) V 50 or 60 Hz
  • Main Unit
: ≤1000 V·A

 

   
  • Cooling Unit
: ≤1000 V·A

 

   
           

Trig-in/out:

  • Trig-in
: TTL/CMOS
  • Trig-out
: TTL/CMOS
  • Trig-in pulse width
: ≥ 200 µs
  • Stimulus delay relative to trig-in signal
: 100...200 µs
  • Trig-out pulse width (user-defined)
  10 µs…50 ms

 

   
           

General Specifications and Parameters:

  • Interface
: USB
  • Safety
: I
  • Cooling unit tank volume while filling up to the maximal level
  3.5 I
  • Work Parts
: BF type
  • Type of cooling agent
: Silicone oil 5 cSt
  • Ingress Protection
: IP20
  • Operation Temperature
: (10–35)º C
  • Relative air humidity
: ≤80%
  • Cooling agent pressure in coil while cooling unit operating
: not more than 0.15 MPa

 

   
           

Stimulation Parameters:

  • Stimulation frequency in repetitive stimulation mode
  • Range of Permissible Values
: (0.1–30) Hz (Stand-alone mode) & (0.1 – 100) Hz (PC Mode)
  • Frequency Step
: 0.1 Hz (0.1 -10 Hz) & 1 Hz (10-100 Hz)
  • Stimulation frequency in burst* mode
  • Range of Permissible Values
: 50 – 100 Hz PC Mode
  • Frequency Step
: 1 Hz
  • Pulse train duration range
  • Range of Permissible Values
: (0.5 - 100)s
  • Frequency Step
: 0.5s(0 - 29.5s) & 0.1s(1.00 - 9.90s)
  • Inter-train interval range
  • Range of Permissible Values
: (0 - 300)s
  • Frequency Step
: 0.5s(0 - 29.5s) & 0.1s(30 - 100s)
  • Session (0.5-40) min 0.5 min
  • Range of Permissible Values
: (0.5 - 40) min
  • Frequency Step
: 0.5 min
           

Capacitor Charge Control:

  • Delay for the capacitor charge start (analysis epoch)**
  • Range of Permissible Values
: (0–9.90) s
  • Frequency Step
: 0.01 s (0–0.99 s), 0.1 s (1.00–9.90s)
           

Trig-out:

  • Trig-out pulse width
  • Range of Permissible Values
: 10 μs, 1 ms–50 ms
  • Frequency Step
: 1 ms

 

Standard Configurations

Neuro-MS/D main unit    :    1
Neuro-MS/D cooling unit    :    1
Patient cap    :    20
Angulated figure-of-eight cooled coil    :    1
Cooled ring coil    :    1
Silicon Oil    :    1
Coil Holder    :    2
Flexible arm for coil positioning    :    1
License for Neuro-MS.NET    :    1
        
Equipment for EEG :        
Neuron-Spectrum-5 electronic unit    :    1
LED photic stimulator    :    1
Floor stand for LED photic stimulator    :    1
EEG Cup electrode with cable    :    30
Electrode system cap    :    1
User manual "Neuron-Spectrum.NET" Soft copy    :    1
License for EEG software module    :    1
        
Aksesoris Lokal :        
PC All in One    :    1
Printer    :    1
Trolley    :    1
UPS    :    1