The device contains 8 high-quality channels with both touch-proof and DIN outputs. Noise-free EMG signals allow using device both for routine EMG studies and during the intraoperative neurophysiological monitoring.
Neuro-MEP-8 takes the convenience and ergonomics of EMG systems to the next level.
Using the dedicated keyboard you can easily start and stop the stimulation, change the stimulus intensity and duration, arrange marker positions, run new tests, start signal monitoring, enter the measured distance, etc. The adjustable electro stimulating probe is equipped with buttons to run single and repetitive stimulation, separate button to change the stimulus polarity and scroller to increase/decrease the stimulus intensity. This probe is convenient to use for right-handed and left-handed specialists. The footswitch with software-controlled buttons to run and stop stimulation frees your hands and lets you focus on complex nerve searching. In case of an infant you can pay more attention to a patient.
Sometimes the myography can not answer all diagnostic questions. Often a neurophysiologist should study also the evoked potentials. Neuro-MEP-8 has built-in stimulators to record EP of all modalities. Besides, the unique software makes this process quick and easy.
Using Neuro-MEP-8 you can perform almost all known EMG, NCS and EP techniques. In recent decades the technique standards are accepted and established. These are special algorithms to study different pathologies, calculations intended for each test, reference values, etc. It is very important for a professional to be equipped with all the techniques even if some of them are used rare. The list of tests made with Neuro-MEP-8 meets the international standards of EMG and EP study.
Neuro-MEP-8 consists of the following units:
|
|
|
|
|
All electronic units are connected to computer via USB. It allows combining them flexibly to arrange a configuration corresponding to your own requirements. For example, to solve intraoperative neurophysiological monitoring tasks, you can use four 4-channel amplifiers instead of two ones and plug in direct nerve stimulator instead of electrical stimulator. To study the sensory conduction collision, plug in the second electrical stimulator into available USB port.
It is possible to connect up to 10 different USB units in different configurations.
|
|
|
|
|
|
|
|
|
|
|
Amplifier: |
|||||
|
: | 8 (4x2) channel |
|
: | not more than 25/22** pF |
|
: | 8 (4x2) channel |
|
: | not more than 0.1 μA |
|
: | 20 μV ±50 mV |
|
: | |
|
: | 0.1±400 μV |
|
: | from -30 up to +5% |
|
: | not less than 100 dB |
|
: | from -10 up to +5% |
|
: | not more than 0.5 μV |
|
: | 0.02 - 3000 Hz |
|
: | not less than 200/1000** MΩ |
|
: | 10 Hz - 10 kHz |
|
: | 0.05 μV/div - 50 mV/div |
|
: | within ±5% |
|
: | 0.1 ms/div - 2 s/div |
|
||
|
Electrical Stimulator: |
|||||
|
: | 0.1–100 mA |
|
: | |
|
: | 25 - 5000 μs |
|
: | 40 - 1000 Hz |
|
: | 0.01 - 100 Hz |
|
: | 50 ms |
|
: | 10 - 100000 ms |
|
||
|
Auditory Stimulator: |
|||||
|
: | 2 (right and left) |
|
: |
50-90000 μs |
|
: | 0 - 130 dB SPL |
|
: | yes |
|
: | 0.01-100 Hz |
|
||
|
Visual Stimulator: |
|||||
|
: | (1100 ± 110) cd/m2 |
|
: | 0.01-100 Hz |
|
0.05-1500 ms |
|
|||
|
General Parameters and Characteristics: |
|||||
|
: |
|
: | USB | |
|
: | 5 V DC |
|
||
|
Minimum Computer: |
|||||
|
|
||||
|
|
||||
|
Software Included: |
|||||
|
|
||||
|
|
||||
|
|
||||
|
|||||
|
: | 2 |
|
: | 1 |
|
: | 1 |
|
: | 1 |
|
: | 1 |
|
: | 1 |
|
: | 1 |
|
: | 1 |
|
: | 1 |
|
: | 1 |
|
: | 1 |
|
: | 1 |
|
: | 1 |
|
: | 1 |
|
: | 1 |
|
: | 1 |
|
: | 1 |
|
: | 1 |
|
: | 1 |
|
: | 8 |
|
: | 1 |
|
: | 1 |
|
: | 1 |
|
: | 1 |
|
: | 1 |
|
: | 2 |
|
: | 2 |
|
: | 10 |
|
: | 25 |
|
: | 1 |
|
: | 1 |
|
: | 2 |
|
: | 1 |
|
: | 1 |
|
: | 1 |
|
: | 1 |
|
: | 1 |
|
: | 1 |
|
Aksesoris Lokal: |
|||||
|
: | 1 |
|
: | 1 |
|
: | 1 |
|
: | 1 |